| SELECTION EXAMPLE | 
| * To choose a coupling for the connection of a 25 HP, electric motor 1750 RPM, service factor 1.0 | 
| * Necessary power times 100 rpm, divided by motor rpm equals (HP per 100) | 
| * 25 hp times 100 = 2,500 divided by 1750 = 1,43 HP / 100 RPM | 
| * Referring to table below and using 1.43 HP /100 RPM , you can select required coupling at various service factor. | 
| Coupling 
          Number | Max RPM  | HP 
          per 100 RPM  | Torque @ 1.0 S.F. (LB in) | ||||
| Service Factors  | |||||||
| 1.0 | 1.15 | 2.0 | 2.5 | 3.0 | |||
| 4500 | 1.43 | .95 | .72 | .57 | .48 | 900 | |
| 4000 | 2.86 | 1.91 | 1.43 | 1.14 | .95 | 1,800 | |
| 3600 | 3.49 | 2.33 | 1.75 | 1.40 | 1.16 | 2,200 | |
| 3100 | 5.71 | 3.81 | 2.86 | 2.28 | 1.90 | 3,600 | |
| 2800 | 6.90 | 4.60 | 3.45 | 2.76 | 2.30 | 4,350 | |
| 2600 | 8.33 | 5.55 | 4.17 | 3.33 | 2.78 | 5,250 | |
| 2300 | 12.30 | 8.20 | 6.15 | 4.92 | 4.10 | 7,750 | |
| 2100 | 19.90 | 13.27 | 9.95 | 7.96 | 6.63 | 12,540 | |
| 1840 | 43.78 | 29.19 | 21.89 | 17.51 | 14.59 | 27,590 | |
| 1560 | 59.98 | 39.99 | 29.99 | 23.99 | 19.99 | 37,800 | |
| 1300 | 130.90 | 87.27 | 65.45 | 52.36 | 43.63 | 82,500 | |